Who we built this for.
People who answer for a building's fire alarm without working in telecom. Each brings us a different problem, and the unit changes something different for each.
Property managers
The problemCopper letters arrive for several addresses at once. Each building has its own alarm company, and the phone bills list numbers nobody has labeled.
What changesSend us the bills. The free audit matches every number to what it runs, building by building, and every building gets the same unit and the same alerts.
Building owners
The problemYou pay every month for copper lines that, on a quiet day, carry little more than a test signal every few hours, and a carrier's letter can set a date to end them.
What changesOne unit carries up to eight lines, so the fire panel, elevator phones and alarm lines move together. You pay a competitive monthly price for each line, on a multi-year term.
Facility managers
The problemYou're the one the inspector, the alarm company and the monitoring center call when a line goes quiet, often after the fact.
What changesEvery line on the unit is monitored, and you get an alert when one drops, so a dead line reaches you and not only the monitoring center. See a sample monthly report.
We built it for older commercial buildings where the fire panel still dials out over copper: offices, mid-rise apartments, senior living, hotels and schools.
What goes wrong, and what the unit does.
Six problems that come with the end of copper, and the unit's answer to each.
| The problem | Why it happens | What the unit does |
|---|---|---|
| The carrier sets a date | The copper letter gives a date to move each line by. What the letter means. | Takes over the line before that date, so the panel is never without one. |
| The power goes out | Copper carried its own power from the phone company. Fiber, cable and cellular service usually need a battery at your end, the FCC says. | Runs on its own battery, rated for up to 24 hours. |
| The one line is cut | A copper line is a single path out of the building. | Gives the line three: your building's internet first, then cellular on two networks with two SIM cards. |
| Everything has to move at once | One letter can list the fire panel's lines, the elevator phones, the burglar alarm and the fax. What elevator lines need. | Carries up to eight phone lines on one unit, so they move together. |
| Nobody notices a dead line | The monitoring center flags a missed test signal. Whether anyone tells you depends on its call list. | Monitors every line on the unit and alerts you when one drops. |
| The fire department asks what you installed | Your local fire department inspects and accepts the installation. | Is UL 864 listed for fire alarm signaling. A licensed alarm company connects the panel and tests it with your monitoring center. |
What NFPA 72 asks for.
The 2025 edition, for a panel that dials its monitoring center over a phone line (a DACT). Your state or city decides which edition applies, and your fire department has the final say.
| What NFPA 72 asks | Section | What it means for your building |
|---|---|---|
| Two separate ways out | 26.6.4.2.5(1) | The panel connects to two separate means of transmission, so a failure on one doesn't affect the other. Ask your alarm company how they will arrange the panel's two connections. |
| A primary line on an MFVN | 26.6.4.2.1, 26.6.4.2.5(3), annex A.3.3.172 | A managed facilities-based voice network: phone service a regulated carrier runs end to end. The annex says equipment that emulates a phone line and sends the signal over IP can provide that line, if it is part of an MFVN. |
| A test every 6 hours | 26.6.4.2.5(6), (7) | Each path sends a test signal to the monitoring center at least every 6 hours, and staff there acknowledge each missed one. |
| 24 hours of backup power | 26.6.3.13 | For the equipment at the building that sends the signals, shared communications equipment included. 8 hours can be allowed where the fire department accepts a risk analysis. |
| Listed equipment | 26.6.3.2.2, 26.6.3.12 | Equipment that sends the signals is listed for the purpose, and shared communications equipment is listed as communications equipment. |
| A test after any change | Annex A.3.3.172 | When the phone service changes, authorized fire alarm service personnel test the system to confirm signals still reach the monitoring center. |
Sources, each read November 21, 2026
- NFPA 72, National Fire Alarm and Signaling Code2025 edition, public copy
- CAL FIRE State Fire Marshal, Information Bulletin 25-006Issued Jul 10, 2025
- FCC, Tech Transitions consumer guideLast reviewed Sep 22, 2025
Your alarm company's communicator, or our unit?
Both are real options. Which one costs less depends on how many systems in your building still use copper.
| Question | Communicator from your alarm company | POTS Replacement Device |
|---|---|---|
| What it carries | The fire panel's signals | Up to eight phone lines: fire, elevator, burglar alarm, call boxes, fax |
| Ways out of the building | Depends on the model; ask your alarm company | Building internet, then cellular on two networks |
| Backup power | Ask your alarm company | Its own battery, up to 24 hours |
| Who connects the fire panel | Your alarm company | A licensed alarm company |
| Lines watched for you | Your monitoring center sees missed tests | Every line on the unit, with an alert to you when one drops |
| The better buy when | Only the fire panel is still on copper | Several systems are still on copper |
If the fire panel is the only thing left on copper, your alarm company's communicator may cost less, so ask them for a quote. If the elevators, the burglar alarm or the fax are on copper too, that is the building the unit was made for.
Questions about fire alarm phone lines.
Sources read . Call (385) 581-3080 if your question isn't here.
Can a fire alarm work without a landline?
Yes. NFPA 72's annex says the panel's phone line can come from equipment that emulates a phone line and sends the signal over IP or another network, as long as that equipment is part of a managed facilities-based voice network (MFVN). The code also allows other communication methods, such as a cellular communicator. Your fire department accepts the result.
What is an MFVN?
A managed facilities-based voice network: phone service a regulated carrier manages from your building to the monitoring center, carrying alarm signals in their original format. NFPA 72 requires a panel that dials out to use one for its primary line. California's state fire marshal says it can't be just hardware; a carrier has to manage the network.
Why does my fire panel have two phone lines?
A panel that dials its monitoring center has to connect to two separate means of transmission, so one failure can't take out both, and a second phone line is one of the ways NFPA 72 allows. In one building we walked in November 2026, the two alarm lines ended at phone jacks marked 1 and 2 on the phone board.
Do I need a new fire alarm panel?
Not for the phone line. The unit gives the panel an analog phone line like the one it has now and carries common alarm formats, including Contact ID and SIA. Your alarm company confirms your panel's format works before the switch.
Who connects it, and who approves it?
A licensed alarm company connects the panel to the unit and runs a test with your monitoring center. POTS Replacement Device does not install, service or maintain alarm systems. Your local fire department inspects and accepts the installation, and nobody can promise its answer in advance.
What does it cost?
A competitive monthly price for each line, on a multi-year term. A fire panel with two lines counts as two. Send a recent phone bill and the free audit prices every line in the building.
Find out which lines are fire lines.
Tick what still runs on copper. Cameron Hoffman, the founder, replies the same business day, matches every number on your phone bill to what it runs, and tells you what moving each fire line costs. The audit is free.
Or call (385) 581-3080 and leave a message.